Functions specific to SCALANCE
3.3 Digital input/output
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
95
3.3.2
show digital output
Description
This command shows the current setting of the digital output.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show digital output
Result
The current setting of the digital output is displayed.
3.3.3
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
3.3.3.1
digital output close
Description
This command closes the digital output.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents