Loading...
Functions specific to SCALANCE
3.5 SINEMA RC
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
113
3.5.4.3
no autofwnat
Note
This command is only available with a KEY
-PLUG.
Description
With this command, you disable the firewall and NAT rules.
Requirement
You are in the SINEMARC configuration mode.
The command prompt is as follows:
cli(config-sinemarc)#
Syntax
Call the command without parameter assignment:
autofwnat
Result
The firewall and NAT rules are disabled.
Further notes
You enable the setting with the autofwnat command.
You display this setting and other information with the
show sinemarc command.