9.3.6.3
auth remcert
Description
With this command you specify that the remote station certificate will be used for
authentication.
Requirement
The certificates are loaded.
You are in the IPSEC AUTHENTICATION configuration mode.
The command prompt is as follows:
cli(config-conn-auth)#
Syntax
Call up the command with the following parameters:
auth remcert <string(255)> localcert <string(255)>
The parameters have the following meaning:
Remote cert
Keyword for a remote station certificate
-
string
Name of the remote station certificate Specify a valid remote station
certificate.
Local cert
Keyword for a device certificate -
string
Name of the device certificate
Specify a valid device certificate.
Result
The setting is configured.
Further notes
You show the loaded certificates with the show-idx command.
You display this setting and other information with the
show ipsec conn-authentication
command.
You remove the authentication with the
no auth command.
9.3.6.4
no auth
Description
With this command, you delete the authentication method.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals