Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
428 Configuration Manual, 06/2015, C79000-G8976-C406-02
To enable the clients, use the client config command.
Note
Changing several message types or clients
With each command call, you can
only select one message type and one client.
If you want to process several message types or clients, it may be more efficient to first
select the all
option and then disable individual elements.
no event config
Description
With this command, you configure which of the various message types of the device will no
longer be stored or forwarded.
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Call up the command with the following parameters:
no event config
{ cold-warmstart | linkchange | authentication-failure | power-change | faultstate-
change | digital-in | vpn-tunnel | all}
{logtable | syslog | email | trap | faults | digital-out | vpn-tunnel | all}
The parameters have the following meaning:
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a status change in the power supply
Message when there is a status change in the error monitoring
Message when there is a status change of the digital input
Message when there is a connection change (OpenVPN, IPsec, SINEMA RC)
Client that processes the log entries
Client that sends the messages to the log server
Client that sends the e-mails