EasyManuals Logo

Siemens SCALANCE S615 Configuration Manual

Siemens SCALANCE S615
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #265 background imageLoading...
Page #265 background image
Network protocols
6.9 Proxy server
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
265
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Proxy server name Specify the proxy server
name.
Maximum of 128 characters
name
User name Specify the user name for
access to the proxy server.
Maximum of 255 characters.
Result
The user name has been changed.
Further notes
You display the available proxy server names with the srv show-names command.
You create the proxy server with the
srv name command.
6.9.3.9
srv show-names
Description
With this command, you display the available proxy server names.
Requirement
You are in the PROXYSERVER configuration mode.
The command prompt is as follows:
cli(config-proxysrv)#
Syntax
Call the command without parameter assignment:
srv show-names
Result
The proxy server names are listed.
Further notes
You create a proxy server with the srv name command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals