Functions specific to SCALANCE
3.5 SINEMA RC
SCALANCE S615 Command Line Interface
112 Configuration Manual, 06/2015, C79000-G8976-C406-02
3.5.4.2
autofwnat
Note
This command is only available with a KEY
-PLUG.
Description
With this command, you enable the automatic creation of the firewall and NAT rules for the
connection to the SINEMA RC Server.
Requirement
You are in the SINEMARC configuration mode.
The command prompt is as follows:
cli(config-sinemarc)#
Syntax
Call the command without parameter assignment:
autofwnat
Result
The automatic firewall and NAT rules are created. The connections between the configured
exported subnets and the subnets that can be reached via the SINEMA RC Server are
allowed. The NAT settings are implemented as configured in the SINEMA RC Server.
Further notes
You enable the setting with the autofwnat command.
You disable the setting with the
no autofwnat command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals