EasyManuals Logo

Siemens SCALANCE S615 Configuration Manual

Siemens SCALANCE S615
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #384 background imageLoading...
Page #384 background image
Security and authentication
9.3 IPsec VPN
SCALANCE S615 Command Line Interface
384 Configuration Manual, 06/2015, C79000-G8976-C406-02
9.3.6.7
rem-id
Description
With this command, you configure the remote ID.
Requirement
You are in the IPSEC AUTHENTICATION configuration mode.
The command prompt is as follows:
cli(config-conn-auth)#
Syntax
Call up the command with the following parameters:
rem-id <string(255)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
string
Remote ID Enter the remote ID.
If you do not specify the remote ID, the remote ID is read from the device
certificate.
If you use PSK as the authentication, the WAN IP address is used as the
remote ID.
Result
The remote ID is configured.
Further notes
You display this setting and other information with the show ipsec conn-authentication
command.
You remove the remote ID with the
no rem-id command.
9.3.6.8
no rem-id
Description
With this command, you remove the remote ID.
Requirement
You are in the IPSEC AUTHENTICATION configuration mode.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE