Configuration
2.1 System
SCALANCE S615 Command Line Interface
60 Configuration Manual, 06/2015, C79000-G8976-C406-02
Call the command without parameter assignment:
no alias
The name of the interface is removed.
You configure the name of the interface with the alias command.
Electrical interfaces can be operated in full duplex mode or half duplex mode. The options
here depend on the connected device.
Optical connections are always operated in full duplex mode since they have a fiber for each
transmission direction.
With this command, you configure the duplex mode of an interface. The same mode must be
set for connected interfaces.
● Autonegotiation is disabled.
● You are in the Interface configuration mode of an electrical interface.
The command prompt is as follows:
cli(config-if-$$$)#
Call up the command with the following parameters:
duplex {full|half}
The parameters have the following meaning:
The Interface will be operated in full
Default: full
The Interface will be operated in half
duplex mode
-