Configuration
2.1 System
SCALANCE S615 Command Line Interface
66 Configuration Manual, 06/2015, C79000-G8976-C406-02
shutdown complete
Description
With this command, you shut down the interface.
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Call the command without parameters:
shutdown complete
The Interface is shut down.
Note
If you use this command in the Interface Configuration mode for a VLAN (input prompt
CLI(config
-if-vlan-$)#, management access to the device is no longer possible. This
relates to configuration using CLI, WBM and SNMP. Access is only possible again after
resetting the device to the factory settings with the Reset button.
You activate the interface with the no shutdown command.
You can display the status of this function and other information with the
show
interfaces
command.