Configuration
2.1 System
SCALANCE S615 Command Line Interface
66 Configuration Manual, 06/2015, C79000-G8976-C406-02
2.1.10.10
shutdown complete
Description
With this command, you shut down the interface.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
shutdown complete
Result
The Interface is shut down.
Note
If you use this command in the Interface Configuration mode for a VLAN (input prompt
CLI(config
-if-vlan-$)#, management access to the device is no longer possible. This
relates to configuration using CLI, WBM and SNMP. Access is only possible again after
resetting the device to the factory settings with the Reset button.
Further notes
You activate the interface with the no shutdown command.
You can display the status of this function and other information with the
show
interfaces
command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals