Configuration
2.2 Load and Save
SCALANCE S615 Command Line Interface
76 Configuration Manual, 06/2015, C79000-G8976-C406-02
Result
The file types are displayed or the file is downloaded to the device.
Further notes
You configure the name of the file with the tftp filename command.
With the "
show loadsave files" command, you can display the file types.
2.2.5.4
tftp save
Description
With this command, you copy a file from the file system of the device to a TFTP server. The
TFTP protocol is used for the transfer. You can also display a list of available files.
Requirement
The name of the file is specified
You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp save {showfiles|filetype<filetype>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
showfiles
Shows the available files
-
filetype
Keyword for a file type to be loaded
-
filetype
Name of the file type
max. 100 characters
Result
The file types are displayed or the file is copied.
Further notes
You configure the name of the file with the tftp filename command.