10.1 Event and fault handling
SCALANCE S615 Command Line Interface
422 Configuration Manual, 06/2015, C79000-G8976-C406-02
10.1.8
logging console
Description
With this command, you enable the logging of inputs and outputs to the console.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
logging console
Result
The logging function is enabled on the console.
Further notes
You disable the setting with the no logging console command.
As default the function is "disabled".
10.1.9
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.