Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
350 Configuration Manual, 06/2015, C79000-G8976-C406-02
Result
The corresponding service is deleted.
Further notes
You display the available service names with the service show-names command.
You create a service with the
service name command.
You display this setting and other information with the
show firewall ip-services
command.
9.2.4.39
service name set prot
Description
With this command, you change the protocol.
Requirement
The service name has been created.
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
service name <string(32)> set proto {udp|tcp}
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Service name Specify a valid service name.
Maximum of 32 characters
UDP
The service is valid only for UDP
frames.
-
TCP
The service is valid only for TCP
frames.
-
Result
The protocol of the relevant service has been changed.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals