EasyManua.ls Logo

Siemens SCALANCE S615 - Service Name Set Prot

Siemens SCALANCE S615
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
350 Configuration Manual, 06/2015, C79000-G8976-C406-02
Result
The corresponding service is deleted.
Further notes
You display the available service names with the service show-names command.
You create a service with the
service name command.
You display this setting and other information with the
show firewall ip-services
command.
9.2.4.39
service name set prot
Description
With this command, you change the protocol.
Requirement
The service name has been created.
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
service name <string(32)> set proto {udp|tcp}
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Service name Specify a valid service name.
Maximum of 32 characters
UDP
The service is valid only for UDP
frames.
-
TCP
The service is valid only for TCP
frames.
-
Result
The protocol of the relevant service has been changed.