Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
426 Configuration Manual, 06/2015, C79000-G8976-C406-02
Parameter
Description
email
Disables the client that sends the e-mails
all
Disables all clients at once
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the show events config command.
You enable the function with the
client config command.
10.1.10.4
event config
Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a status change in the power supply
Message when there is a status change in the error monitoring
Message when using VPN
Message when using firewall rules
Message when changing the connection status
Message on connection establishment and when the configuration changes
Message when there is a status change of the digital input.
These messages can be processed by the clients in different ways:
Entry in the logbook of the device
Sending the message to the Syslog server of the system
Sending an e-mail
Sending an SNMP trap
Lighting up of the error LED
Switching at the digital output