EasyManuals Logo

Siemens SCALANCE S615 Configuration Manual

Siemens SCALANCE S615
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
System time
4.1 System time setting
SCALANCE S615 Command Line Interface
124 Configuration Manual, 06/2015, C79000-G8976-C406-02
4.1.2.1
time
Description
With this command, you configure the way in which the system time is obtained.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time{manual|ntp|sntp|SINEC}
The parameters have the following meaning:
Parameter
Description
manual
The system time is entered by the user
ntp
The system time is obtained from an NTP server
sntp
The system time is obtained from an SNTP server
SINEC
The system time is obtained using the "SIMATIC time protocol"
Result
The method of obtaining the system time is configured.
Further notes
You display the settings for the system clock with the show time command.