Page #103 background image
Functions specific to SCALANCE
3.4 SRS
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
103
Result
The specified destination server entry is deleted.
Further notes
You create a destination server entry with the logon addr command.
You display the numbers of the destination servers with the
logon show-idx command.
3.4.3.5
logon idx addr
Note
This command is only available with a KEY
-PLUG.
Description
With this command, you change address of a specific destination server.
Requirement
You are in the SRS configuration mode.
The command prompt is as follows:
cli(config-srs)#
Syntax
Call up the command with the following parameters:
logon idx <num(1-100)> addr <ip_addr|dns(50)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
num
Number corresponding to a specific
destination server.
Enter the required number.
ip_addr
IPv4 address Enter the IPv4 address of the
proxy server.
dns
DNS host name Enter the DNS host name of the
proxy server.
Maximum of 50 characters
Result
The address of the destination server has been changed.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals