Network protocols
6.10 SMTP client
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
269
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
no sender mail-address
Result
The e-mail name of the sender is reset.
Further notes
You configure the e-mail name of the sender with the sender mail-address.
You display the setting with the
show events sender email command.
6.10.2.3
smtp-server
Description
With this command, you configure an entry for an SMTP server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-server {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} <receiver mail-address>
The parameters have the following meaning:
Parameter
Description
Note on the range if values
ipv4
Keyword for an IP address
-
ucast_addr
Value for an IPv4 unicast address Enter a valid IPv4 unicast ad-
dress.
fqdn-name
Keyword for a domain name
-