Result
The automatic negotiation of connection parameters on an interface is deactivated.
Further notes
You enable the autonegotiation of connection parameters with the negotiation command.
2.1.10.9
mtu
Description
With this command, you configure the size of the Maximum Transmission Unit (MTU) for an
interface.
Requirement
The Interface must be shut down.
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
mtu <frame-size(64-1500)>
The parameter has the following meaning:
Parameter
Description
Range of values
frame-size
Size of the MTU in bytes
64 ... 1500
At system start or when using the restart command with the option memoryor factory, the
following defaults apply:
The size of the MTU is configured to 1536 bytes.
Result
The setting for the size of the MTU is configured.
Further notes
You can shut down the interface with the shutdown complete command.
You display this setting with the
show interface mtu command.
You display this setting and other information with the
show interfaces command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals