Network protocols
6.6 SNMP
SCALANCE S615 Command Line Interface
232 Configuration Manual, 06/2015, C79000-G8976-C406-02
Parameter
Description
Range of values / note
read
the data can be read
Keyword
ReadView
none
write
the data can be read and written
Keyword
WriteView
none
notify
Changes can be set as a tag
Keyword
NotifyView
none
Storage type specifies whether the settings remain following
a restart
volatile (volatile):
The settings are lost after a
restart
nonvolatile (non-volatile):
The settings are retained after
a restart
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the no snmp access command.
You display the configured SNMP groups with the
show snmp group command.
You display the access configurations for SNMP groups with the
show snmp group access
command.
You display the configured SNMP tree views with the
show snmp viewtree command.
6.6.2.5
no snmp access
Description
With this command, you delete the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#