Network protocols
6.6 SNMP
SCALANCE S615 Command Line Interface
232 Configuration Manual, 06/2015, C79000-G8976-C406-02
Parameter
Description
Range of values / note
read
the data can be read
Keyword
•
ReadView
•
none
write
the data can be read and written
Keyword
•
WriteView
•
none
notify
Changes can be set as a tag
Keyword
•
NotifyView
•
none
Storage type specifies whether the settings remain following
a restart
•
volatile (volatile):
The settings are lost after a
restart
•
nonvolatile (non-volatile):
The settings are retained after
a restart
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the no snmp access command.
You display the configured SNMP groups with the
show snmp group command.
You display the access configurations for SNMP groups with the
show snmp group access
command.
You display the configured SNMP tree views with the
show snmp viewtree command.
6.6.2.5
no snmp access
Description
With this command, you delete the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE