Security and authentication
9.3 IPsec VPN
SCALANCE S615 Command Line Interface
404 Configuration Manual, 06/2015, C79000-G8976-C406-02
9.3.8.9
lifebyte
Description
With this command, you configure the data limit to specify the lifetime of the agreed keys.
When the data limit is reached, the key is renegotiated.
Requirement
You are in the IPSEC PHASE configuration mode.
The command prompt is as follows:
cli(config-conn-phs2)#
Syntax
Call up the command with the following parameters:
lifebyte <integer(0-4294967295)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
integer
Data limit
Enter the data limit in bytes.
Result
The data limit is configured.
Further notes
You display this setting and other information with the show ipsec conn-phase2 command.