EasyManuals Logo

Siemens SCALANCE S615 Configuration Manual

Siemens SCALANCE S615
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #326 background imageLoading...
Page #326 background image
Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
326 Configuration Manual, 06/2015, C79000-G8976-C406-02
9.2.4.13
ipv4rule set from
Description
With this command, you change the outgoing direction.
Requirement
The IPv4 firewall rule has been created.
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
ipv4rule idx <number(1-100)> set from <string(50)> [<integer(0-4094)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
idx
Keyword for index
-
number
Number corresponding to a spe-
cific IPv4 rule.
Enter the required number.
1 ... 100
from
Keyword for the outgoing direc-
tion (from)
-
string
Interface that sends the IPv4
packet
Specify a valid interface.
Maximum of 50 characters
integer
Number of the interface
0 ... 4094
For information on identifiers of addresses and interfaces, refer to the section "Commands in
the FIREWALL configuration mode".
Result
The outgoing direction of the corresponding IPv4 firewall rule has been changed.
Further notes
You display this setting and other information with the show firewall ip-rules ipv4
command.
You obtain the numbers with the
ipv4rule show-rules command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals