Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
314 Configuration Manual, 06/2015, C79000-G8976-C406-02
In the Global configuration mode, enter the firewall command to change to this mode.
If you exit the FIREWALL configuration mode with the
exit command, you return to the
Global configuration mode.
If you exit the FIREWALL configuration mode with the
end command, you return to the
Privileged EXEC mode.
Available interfaces
As the source and destination interfaces, the following interfaces are available:
Interface
prede-
fined
firewall
rules
own firewall
rules
VLAN
VLANs with configured subnet
x
x
vlan (1-x)
PPP
(M874,
M876-3)
WAN interface EGPRS, GPRS,
UMTS
x x
ppp 0
USB
(M876-4)
WAN interface LTE x x
usb 0
IPsecVPN
All IPsecVPN connections
-
x
ipsecALL
Specific IPsecVPN connection
-
x
ipsec num
SINEMA RC
Connection to SINEMA RC Server
-
x
sinemarcall
Device
Connection to the device
-
x
device
x: available
- : not available
9.2.4.1
icmp name
Description
With this command, you create an ICMP service. You select a service name and assign the
service parameters to it.
Requirement
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
icmp name <string(32)> type <num(0-256)> code <num(0-256)> ver ipv4