System time
4.3 SNTP client
SCALANCE S615 Command Line Interface
136 Configuration Manual, 06/2015, C79000-G8976-C406-02
4.3.6.3
no sntp unicast-server ipv4
Description
With this command, you delete the attributes for an SNTP unicast server and reset the
address.
Requirement
You are in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
no sntp unicast-server ipv4<ucast_addr>
The parameters have the following meaning:
Parameter
Description
Range of values
ucast_addr
Value for an IPv4 unicast address
Enter a valid IPv4 unicast address.
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The SNTP unicast server is reset to the default value.
Further notes
You configure the setting with the sntp unicast-server ipv4 command.
You display this setting and other information with the
show sntp unicast–mode status
command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals