Security and authentication
9.3 IPsec VPN
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
371
The parameter has the following meaning:
Parameter
Description
Range of values / note
subnet
Subnet from which the remote
station is offered a virtual IPv4
address
Specify the subnet in CIDR notation.
For information on identifiers of addresses and interfaces, refer to the section "Auto-
Hotspot".
Result
The subnet is configured.
Further notes
You display this setting and other information with the show ipsec remoteend command.
You disable the setting with the
no vir-ip command.
9.3.4.6
no vir-ip
Description
With this command, you specify that the remote station is not offered a virtual IPv4 address.
Requirement
You are in the IPSEC REMOTE END configuration mode.
The command prompt is as follows:
cli(config-ipsec-rmend-X)#
Syntax
Call the command without parameter assignment:
no vir-ip
Result
The setting is configured.
Further notes
You display this setting and other information with the show ipsec remoteend command.
You enable this setting with the vir-ip command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE