Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
316 Configuration Manual, 06/2015, C79000-G8976-C406-02
Syntax
Call up the command with the following parameters:
no icmp {name <string(255)> | all}
The parameters have the following meaning:
Parameter
Description
Range of values / note
name
Keyword for ICMP service name
-
string
ICMP service name Specify a valid service name.
Maximum of 255 characters
all
Deletes all ICMP service names
-
Result
The corresponding ICMP service is deleted.
Further notes
You create the ICMP service with the icmp name command.
You display the available service names with the
icmp show-names command.
You show the available ICMP packet types and codes with the
icmp show-types-codes
command.
9.2.4.3
icmp name set
Description
With this command, you change the ICMP packet type and the code.
Requirement
The corresponding ICMP service is has been created.
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
icmp name <string(255)> set type <num(0-256)> code <num(0-256)>

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals