Security and authentication
9.2 Firewall
SCALANCE S615 Command Line Interface
316 Configuration Manual, 06/2015, C79000-G8976-C406-02
Syntax
Call up the command with the following parameters:
no icmp {name <string(255)> | all}
The parameters have the following meaning:
Parameter
Description
Range of values / note
name
Keyword for ICMP service name
-
string
ICMP service name Specify a valid service name.
Maximum of 255 characters
all
Deletes all ICMP service names
-
Result
The corresponding ICMP service is deleted.
Further notes
You create the ICMP service with the icmp name command.
You display the available service names with the
icmp show-names command.
You show the available ICMP packet types and codes with the
icmp show-types-codes
command.
9.2.4.3
icmp name set
Description
With this command, you change the ICMP packet type and the code.
Requirement
The corresponding ICMP service is has been created.
You are in the FIREWALL configuration mode.
The command prompt is as follows:
cli(config-fw)#
Syntax
Call up the command with the following parameters:
icmp name <string(255)> set type <num(0-256)> code <num(0-256)>