Configuration
2.1 System
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
47
Further notes
You exit the Global configuration mode with the end command.
2.1.4
clear line vty
Description
With this command, you close a console session on the device.
With the
forceful-clear option, you close a session and that is not reacting.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
clear line vty {<line-number(2-9)>|all}[forceful-clear]
The parameters have the following meaning:
Parameter
Description
Range of values / note
line-number
Number of the connection that will be
terminated
2 ... 9
all
terminates all connections
-
forceful-clear
closes a session that is not reacting
-
Result
The console session is closed.
Further notes
You show the logged-on users with the show users command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals