Security and authentication
9.3 IPsec VPN
SCALANCE S615 Command Line Interface
390 Configuration Manual, 06/2015, C79000-G8976-C406-02
Further notes
You display this setting and other information with the show ipsec conn-phase1 command.
You enable DPD with the
dpd command.
9.3.7.7
dpd-period
Description
With this command, you configure the period after which DPD queries are sent.
Requirement
DPD is enabled
You are in the IPSEC PHASE configuration mode.
The command prompt is as follows:
cli(config-conn-phs1)#
Syntax
Call up the command with the following parameters:
dpd-period <sec(10-120)>
The parameter has the following meaning:
Parameter
Description
Range of values / note
sec
Period for DPD queries Enter the period of time in sec-
onds.
Result
The period of time is configured.
Further notes
You display this setting and other information with the show ipsec conn-phase1 command.
You enable DPD with the
dpd command.