Network protocols
6.6 SNMP
SCALANCE S615 Command Line Interface
248 Configuration Manual, 06/2015, C79000-G8976-C406-02
If optional parameters are not specified when configuring an SNMP user, the defaults values
apply.
Result
The details of the SNMP user are configured.
Further notes
You delete the settings with the no snmp user command.
You display the configured users with the
show snmp user command.
6.6.2.21
no snmp user
Description
With this command, you delete the details of an SNMP user.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp user <UserName>
The parameter has the following meaning:
Parameter
Description
Range of values / note
UserName
Name of the user
max. 32 characters
Result
The details of the SNMP user are deleted.
Further notes
You change the settings with the snmp user command.
You display the configured users with the
show snmp user command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals