Configuration
2.1 System
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
59
2.1.10.1
alias
Description
With this command, you assign a name to an interface. The name only provides information
and has no effect on the configuration.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
alias <port-name>
The parameter has the following meaning:
Parameter
Description
Range of values / note
port-name
Name of the interface
max. 63 characters
Result
The interface was assigned a name.
Further notes
You delete the name of the interface with the no alias command.
2.1.10.2
no alias
Description
With this command, you delete the name of the interface.