Configuration
2.2 Load and Save
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
75
The parameters have the following meaning:
Parameter
Description
Range of values / note
showfiles
Shows the available files
-
filetype
Keyword for a file type to be assigned
a name
-
filetype
Name of the file type
max. 100 characters
name
Keyword for a file name to be assigned
to the file type
-
filename
Name of the file
max. 100 characters
Result
The file types are displayed or the file type is assigned a name.
Further notes
With the "show loadsave files" command, you can display the file types.
2.2.5.3
tftp load
Description
With this command, you load a file from a TFTP server into the file system of the device. The
TFTP protocol is used for the transfer. You can also display a list of available files.
Requirement
The name of the file is specified
You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp load{showfiles|filetype<filetype>}
The parameters have the following meaning:
Parameter
Description
Range of values / note
showfiles
Shows the available files
-
filetype
Keyword for a file type to be loaded
-
filetype
Name of the file type
max. 100 characters

Table of Contents