EasyManua.ls Logo

Siemens SCALANCE S615 - No User-Account; Username

Siemens SCALANCE S615
442 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Security and authentication
9.1 User rights management
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
307
9.1.4.2
no user-account
Description
With this command, you delete a user.
Note
Apart from the users "admin" and "user", they can all be deleted.
Requirement
The user has been created.
The user is logged in with the "admin" role.
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-account <user-name>
The parameter has the following meaning:
Parameter
Description
Range of values / note
user-name
User name
Enter a valid user name.
Result
The user has been deleted.
Further notes
You create a user with the user-account command.
You show the created users with the
show user-accounts command.
9.1.4.3
username
Description
With this command, you change the password of the factory set user "admin".

Table of Contents

Other manuals for Siemens SCALANCE S615

Related product manuals