Network structures
5.1 VLAN
SCALANCE S615 Command Line Interface
156 Configuration Manual, 06/2015, C79000-G8976-C406-02
5.1.3.2
no map subnet
Description
With this command, you remove a subnet from a VLAN.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no map subnet <ip-subnet-address>
The parameters have the following meaning:
Parameter
Description
Range of values / note
ip-subnet-address
IP subnet address
Enter a valid subnet address
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The subnet with subnet mask and subnet address is assigned to a VLAN.
Further notes
You configure the setting with the map subnet command.
You can display the status of this function and other information with the
show subnet-vlan
mapping
command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals