Page #178 background image
Network protocols
6.1 IPv4 protocol
SCALANCE S615 Command Line Interface
178 Configuration Manual, 06/2015, C79000-G8976-C406-02
6.1.2.4
no ip echo-reply
Description
With this command you stop the network node reacting to ping queries.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no ip echo-reply
Result
"ICMP echo reply messages" are disabled. The network node does not react to ping queries.
Further notes
You change the setting with the ip echo-reply command.
6.1.2.5
ip route
Description
With this command, you configure a static entry in the IP routing table.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip route <prefix> <mask> <next-hop> [<distance(1-255)>]

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals