System time
4.3 SNTP client
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
131
4.3
SNTP client
4.3.1
show commands
This section describes commands with which you display various settings.
With the command
do [command] you can execute the "show" commands in every
configuration mode.
To do this, you replace
[command] with the "show" command that you want to execute.
Example
do show cli-console-timeout
This section describes commands relevant for configuration of the SNTP client.
4.3.2
show sntp broadcast-mode status
Description
This command shows the current configuration of the broadcast mode of SNTP.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show sntp broadcast-mode status
Result
The current SNTP broadcast configuration is displayed.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals