Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
415
10.1.1.6
show fwlog
Description
With this command, you show the messages that occurred in the firewall. The messages can
be filtered according to the event severity.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show fwlog [{ info | warning | critical }]
Parameter
The parameters have the following meaning:
Parameter
Description
Range of values / note
info
Information
-
warning
Warnings
-
critical
Critical messages
-
If you use the command without setting parameters, all messages are displayed.
Result
The content of the firewall log is displayed.
10.1.1.7
show logbook
Description
With this command, you display the content of the logbook.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals