Functions specific to SCALANCE
3.5 SINEMA RC
SCALANCE S615 Command Line Interface
110 Configuration Manual, 06/2015, C79000-G8976-C406-02
You exit the Global configuration mode with the end or exit command and are then in the
Privileged EXEC mode again.
3.5.3.1
sinemarc
Note
This command is only available with a KEY
-PLUG.
Description
With this command, you change to the SINEMARC configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
sinemarc
Result
You are now in the SINEMARC configuration mode.
The command prompt is as follows:
cli(config-sinemarc)#
Further notes
You exit the SINEMARC configuration mode with the end or exit command.
3.5.4
Commands in the SINEMARC configuration mode
This section describes commands that you can call up in the SINEMARC configuration
mode.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals