Network protocols
6.9 Proxy server
SCALANCE S615 Command Line Interface
260 Configuration Manual, 06/2015, C79000-G8976-C406-02
6.9.3.3
srv name addr
Description
With this command, you change the address of the proxy server.
Requirement
The proxy server name has been created.
You are in the PROXYSERVER configuration mode.
The command prompt is as follows:
cli(config-proxysrv)#
Syntax
Call up the command with the following parameters:
srv name <string(128)> addr <ip_addr|dns(50)>
The parameters have the following meaning:
Parameter
Description
Range of values / note
string
Proxy server name Specify the proxy server
name.
Maximum of 128 characters
ip_addr
IPv4 address Enter the IPv4 address of the
proxy server.
dns
DNS host name Enter the DNS host name of
the proxy server.
Maximum of 50 characters
Result
The IPv4 address of the proxy server has been changed.
Further notes
You display the available proxy server names with the srv show-names command.
You create the proxy server with the
srv name command.

Table of Contents

Other manuals for Siemens SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE S615 and is the answer not in the manual?

Siemens SCALANCE S615 Specifications

General IconGeneral
ProtocolsIPsec, OpenVPN
Power Supply24 V DC
Mounting TypeDIN Rail
Product NameSCALANCE S615
Ports5
FirewallYes
Weight0.6 kg
CertificationsCE

Related product manuals