Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
427
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Call up the command with the following parameters:
event config
{ cold-warmstart | linkchange | authentication-failure | power-change | faultstate-
change | digital-in | vpn-tunnel | all}
{logtable | syslog | email | trap | faults | digital-out | vpn-tunnel | all}
The parameters have the following meaning:
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a status change in the power supply
Message when there is a status change in the error monitoring
Message when there is a status change of the digital input
Message when there is a connection change (OpenVPN, IPsec,
Client that processes the log entries
Client that sends the messages to the log server
Client that sends the e-mails
Client that sends the SNMP traps
Error LED lights up. The setting is possible only for a cold or warm
Controls the digital output or signals the status change with the
Controls the VPN connection (establishment/termination).
The setting deciding which message of the device is stored or forwarded is configured.
You display the status of the events and the clients with the show events config command.
You delete the settings with the
no event config command.
With this command, the clients are not enabled.