Network protocols
6.7 HTTP server
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
253
no ip http
Result
HTTP is disabled on the device.
Further notes
You can display the setting of this function and other information with the show ip http
server status
command.
You enable HTTP with the
ip http command.