Configuration
2.3 Reset and Defaults
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
81
Syntax
Call up the command with the following parameters:
restart[{memory|factory}]
The parameters have the following meaning:
if no parameters are specified: restarts the system with the current configuration
Parameter
Description
memory
Resets the system to the factory configuration settings and restarts the system.
The parameters listed above are unaffected by a reset.
factory
Resets the system to the factory configuration settings and restarts the system.
Note
By resetting to the factory configuration settings, the device loses its configured IP address
and is reachable again with the IP address 192.168.1.1 set in the factory.
Result
The device is restarted with the selected settings.