Automatic machine parameters Instruction manual GLM-I
254 38.019.129.001 en
20
20.2.5 Enter the maximum package height
If the device is equipped with a motorized height adjustment for labelers, the different
package heights can be saved in the automatic labeler parameter tables. When calling up
an article that an automatic labeler parameter table is assigned to, the labeler is automati-
cally adjusted to the respective package height. The labeler height can also be adjusted
automatically using the softkeys or the keys located on the labeler.
The motorized height adjustment for labelers is available and activated.
Mode level: 1
Modify package height for current labeling job
<Device menu> / <Labeler> / <Labeler man. offset>
Enter value and confirm.
The labeler is automatically adjusted to the relevant package height. The setting is not ap-
plied to the database
.
20.2.6 Adjusting labeler height by means of softkeys
If the device is equipped with a motorized height adjustment for the labeler, the labeler
height can be automatically adjusted using the softkeys
. The labeler height can also be ad-
justed automatically using the keys located on the labeler. If package height is saved un-
der the automatic labeler parameters, the labeler height is changed in the event of a PLU
change.
During height adjustment of the labeler, there must not be any pack-
ages under the labeler
.
The following functions are available:
<Labeler UP>:
Start height adjustment upwards.
<Labeler DOWN> Start height adjustment downwards.
<Labeler STOP> Stop height adjustment.
After stopping the motorized height adjustment via the softkeys, the set height is displayed
in the <Max. pckg. height> softkey.
The motorized height adjustment for labelers is available and activated.
Mode level: 1
<Device menu> / <Labeler> / <Labeler man. offset>