EasyManuals Logo

Bizerba GLM-I User Manual

Bizerba GLM-I
505 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #323 background imageLoading...
Page #323 background image
Instruction manual GLM-I Weight classes and statistics
38.019.129.001 en 321
23
23.1.12 Selection criteria for editing weight class tables via the input
assistant
There are no dividers available for GLM-I.
The following selection criteria are supported:
"Weight determination"
The device weighs all packages
. The statistical evaluation includes all packages. Package
selection does not take place based on statistics. Settings are required for the following at-
tributes:
"Nominal weight": Nominal weight of the article.
"Divider": Specify package separator or switch if you want packages to be
sorted out or redirected. In the standard setting "Do not eject"
packages are not redirected or separated.
"Statistics": Activate, if you want a statistical evaluation to be carried out on
all packages.
Depending on the configuration, a package separator or a divider can
separate or redirect faulty or not-faulty packages
. Faulty packages are
caused, for example, by separation errors.
"Checking contents"
The device executes a check for completeness based on the package weight
; e. g. num-
ber of screws in a box. Settings are required for the following attributes:
"Too light": Limit value after which the package is deemed too light. Specify
package separator or switch if you want packages that are too
light to be separated. In the standard setting "Do not eject" no
packages are separated.
"Good": Upper limit value up to which the packages are considered OK.
Specify package separator or switch if you want the accepted
packages to be separated. In the standard setting "Do not eject"
no packages are separated.
"Too heavy": Limit value after which the package is deemed too heavy. The
value is identical to the "good" value. That is why no input can
be made here. Specify package separator or switch if you want
the packages that are too heavy to be separated. In the stand-
ard setting "Do not eject" no packages are separated.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bizerba GLM-I and is the answer not in the manual?

Bizerba GLM-I Specifications

General IconGeneral
BrandBizerba
ModelGLM-I
CategoryLabel Maker
LanguageEnglish

Related product manuals