Weight classes and statistics Instruction manual GLM-I
332 38.019.129.001 en
23
23.2.5 Creating customer-specific statistics reports
There is a standard report template ("default" and 10 customer-specific modifiable report
templates for each statistic ("Statistics report 1" to "Statistics report 10").
You assign the report templates to the statistics as follows:
via the weight class tables, see page 313
via the function <Select stat.- report>, see page 327
The statistics reports 1 - 10 are preconfigured at the works.
You can set the following default values in the report templates:
"Designation
": Name of report template.
"Formatting rule": The following settings are possible:
"no": The device prints the attributes in the same order as
in the table.
"With": The attributes are combined into categories.
For individual report contents you can define the channels by which the content should be
transmitted for each report template. The channels A-G are connections to the EDP sys-
tem, to a storage medium or to external printers. The "internal" channel is the connection
to the internal label printer.
You can assign the content of a report to as many as the supported transmission channels
as you want. Report contents displayed in gray are subject to a set allocation which you
cannot change here.
The transmission channels are assigned in a customer-specific manner.
How the channels are configured is not part of this documentation
. For
further information please contact your Bizerba consultant or Bizerba
Service.
If you want define the same settings for all customer-specific report, tap
the respective field in the left-hand column
. This causes the complete
table row to be marked. A security check appears. If you answer <yes>
the following input is applied to all customer-specific reports.
Mode level: 5
<Main menu> / <Processing> / <Weight class &statistics> / <Statistics report> /
<Stat.report contents>
Select the "Designation" field from the column in the report template you are editing.
Enter and confirm the name you want.