Instruction manual GLM-I Troubleshooting
38.019.129.001 en 359
25
25.4.5 Print log book of metal detector
Only for devices with a metal detector. The protocols in this logbook document the com-
plete production process. The documentation guidelines set by HACCP regulations are ful-
filled.
The following print functions are available:
"Archive protocol": The protocol contains the following information including date
and time. Information is listed chronologically in the protocol.
The device deletes all information once it has been completely
printed without any errors:
– Metal detection
– Errors and operational interruptions that have occurred
– Product change
– Changes to the device setting togs
– Start, end and progression of the test routines
"Temporary protocol": Same content as "Archive protocol". The device does not de-
lete information after it has been completely printed out without
any errors.
"Product statistics": Statistics contain the following information:
– Begin and end of inspection of a specific product
– Device settings
– Statistical data about the number of products, metal detec-
tion and errors
"Charge statistics": Same content as "Product statistics". Use this statistics if you
produce the same product for different brands or chain of
stores.
"Data on device": The printout contains information on the device and its settings:
– Production line, device identification, date, time
– Software status, search frequency, conveyor speed
– activated/deactivated functions
– Intervals for test routines
– Number of metal detections and error messages since
commissioning
– Settings for the various products
"Audit report": For each inspection routine, the device checks the actions and
results that have been carried out. The report is printed as soon
as the inspection has been concluded properly.
Mode level: 5
<Service menu> / <System services> / <Service printouts> / <Log metal detector>
Select the function you want and close the table.
The device sends data to the printer that has been configured.