23.1.14 Enter the minimum and maximum weight
Checks to inspect the minimum and maximum weight help sort out the following packages:
– non-isolated packages that could be taken for a single package
– Empty packages
– Third-party packages
The check functions as follows in cooperation with the weight class:
– Packages less than the minimum weight are treated in accordance with the settings in
the first weight class column.
– Packages over the maximum weight are treated in accordance with the settings in the
last weight class column.
A check against the minimum and maximum weight limits can also be performed without a
weight class. Packages that are under the minimum weight or over the maximum weight
are treated as faulty and are usually separated.
You can handle the minimum and maximum weight by configuring the PLU data in the da-
tabase respectively. The values are automatically called up when the PLU is changed.
You can enter the minimum and maximum weight directly or change the value temporarily.
Mode level: 2
Enter minimum or maximum weight directly or change temporarily
<Article data> / <Weight> / <Etc>
Press <Minimum weight>.
or
Press <Maximum weight>.
Enter value and confirm.
23.1.15 Enter start value for sliding content check
This is where you can enter a start value for the sliding content check. This value is used
instead of the nominal weight
, see page 320. The value is saved in the device and applies
until a new value is set. It is not saved in the database.
If the entered start value is "0", the nominal weight of the PLU is used
as the start value for the sliding content check
.
Mode level: 2
<Article data> / <Weight> / <Etc> / <Start val.sl. cont.check>
Enter and confirm the start value you want.