Maintenance Instruction manual GLM-I
386 38.019.129.001 en
28
28.5.2 2-shift operation
(approx. 100,000 labels per day)
Labeler
Activity Interval Cleaning agent/
lubricant
General Clean point of reversal of la-
bels and TTF material.
10 days Label remover,
95943000000
Platen printer Clean printer roller, stripping
roller.
5 days Roller cleaner,
94008900088
Replace printer roller, strip-
ping roller
.
4 weeks
Platen printer Clean thermal bar. After every label
roll
Cleaning set,
50777050000,
94008900133
Grease printer and stripping
roller bearing.
4 weeks Roller cleaner,
94008900088
Platen printer Clean guide roller and grease
bearing.
8 weeks Roller cleaner,
94008900088
Lubrication,
96055080000
EcoMotion Printer Replace felt bar, see
page 382.
4 days
Clean stripping roller. 5 days Roller cleaner,
94008900088
EcoMotion Printer Replacing the stripping roller. 4 weeks
Clean guide roller and grease
bearing.
8 weeks Roller cleaner,
94008900088
Lubrication
,
96055080000
EcoMotion Printer Clean thermal bar. After every label
roll
Cleaning set,
50777050000
Cleaning set
,
94008900133
Air-jet head Clean suction plate. Daily Label remover,
95943000000
Bottom air-jet la-
beler
Grease and move splined
shaft
2 days Lubrication,
96055080000