EasyManua.ls Logo

Bizerba GLM-I - Selecting Polarity

Bizerba GLM-I
505 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Automatic machine parameters Instruction manual GLM-I
266 38.019.129.001 en
20
20.9.2 Selecting polarity
For the package ejector or the dividers, the active signal level can be set accordingly. Ex-
ample: Package ejector. The procedure for dividers is analog. The following settings are
possible:
"+": Positive logic. A signal change from 0 V to +24 V is an active
signal. Standard setting.
"-": Negative logic. A signal change of +24 V to 0 V is an active sig-
nal.
Mode level: 5
Select polarity for package ejector.
<Automat> / <Dividers> / <Package ejector> / <Polarity pckg. eject.>
Tap the softkey until the required setting is highlighted.

Table of Contents

Related product manuals