Processing Instruction manual GLM-I
272 38.019.129.001 en
21
21 Processing
21.1 Configuring resolution for label printing
You can set a variety of resolution types for label printing. The following settings are possi-
ble:
<Automatic>:
Print labels automatically after scales at rest.
<Manual>: Start label printing manually.
<Start autom. labeler>: Print label automatically as soon as the package is in the label-
ing system. Standard setting.
<External start>: Start label printing externally.
<Remote device>: For slave device: Start label printing from higher-ranking master
device.
<Remote aut.labeler>: Only for slave labelers linked to double labelers: Start label
printing from higher-ranking master labeler.
<Remote inactive>: Only for slave labelers linked to double labelers: Do not allow
label printing to be started by higher-ranking master labeler.
Mode level: 2
<Processing> / <Release mode> / <Process>
Press softkey with respective setting.
21.2 Switch on and apply automatic PLU change
If the PLU is changed automatically, while one PLU is being labeled, you can already enter
the stipulations for the next PLU that has to be labeled
. This makes sense for small quanti-
ties of PLUs and therefore frequent PLU changes. The PLU change takes place once a
preselected total has been reached.
To activate automatic PLU change, enter the following data into a table:
"PLU No.": PLU number of PLU to be labeled after the PLU change. The
input field is blocked if the "passive" operating mode is set.
"Customer No.:": If necessary, the customer number of the PLU to be labeled af-
ter the PLU change. The input field is blocked if the "passive"
operating mode is set.