Instruction manual GLM-I Weight classes and statistics
38.019.129.001 en 323
23
Settings are required for the following attributes:
"Range 1 to", "Range 2
to" etc.:
Each line corresponds to a weight class
.
"Limiting value": Upper limit value for the appropriate weight class.
"Ejector": Specify switch or package ejector if you want packages that are
in the weight range to be separated. In the standard setting "Do
not eject" no packages are separated.
"FPV Europe"
The device checks and manages the packages in line with European prepack regulations
(FPV). Settings are required for the following attributes
:
"Nominal weight" Nominal weight of the article.
"TO": Upper tolerance weight: The device calculates the upper toler-
ance weight in accordance with prepack regulations from the
nominal weight. You can change the value.
"TU1", "TU2": Lower tolerance weight: The device calculates the lower toler-
ance weight in accordance with prepack regulations from the
nominal weight. You can change the values.
"max. lower tolerance2": Maximum share of packages in the weight range LT1 and LT2:
The device calculates the percentage value. You cannot
change the value.
"Too light": Specify a divider or package ejector if too light packages should
be sorted. In the standard setting "Do not eject" no packages
are separated.
"Good": Specify the divider or package ejector when accepted packages
need to be ejected. In the standard setting "Do not eject" no
packages are separated.
"Too heavy": Specify a divider or package ejector if too heavy packages
should be sorted. In the standard setting "Do not eject" no pack-
ages are separated.
"USA - Non USDA standardized"
This selection criteria is valid for all non meat and poultry products
. It is also valid for all
meat and poultry products that are not produced in factories monitored by the USDA au-
thorities. The device checks and manages the packages in accordance with the specifica-
tions of "NIST Handbook 133". The device accepts all packages with a statistical mean
value that is equal or larger than the nominal weight. There is only a lower tolerance limit
LT1.