Weight classes and statistics Instruction manual GLM-I
314 38.019.129.001 en
23
"Contents of statistics
display":
This is where you can make a setting to have the statistical
evaluation for this weight class column shown in the statistics
display. In the standard setting, the statistical evaluation for the
average weight class column is displayed showing the preset
nominal weight
, Qn.
Only one column can ever be displayed at a time from the
weight class table. If you activate the statistics display for a
weight class column, the respective checkmark is automatically
removed from the other columns.
"Report main statistic": To create a standard statistics report for the main statistics, se-
lect the "default" setting. In your system up to 10 customer-spe-
cific statistics reports can be added, see page 332. In order to
use one of these statistics reports, select one of the respective
settings "Statistics report 1"to "Statistics report 10".
"Report marginal statis-
tic":
Marginal statistics are additional statistics, which are initiated
according to other criteria, see page 328. The contents of the
report correspond to the contents of the main statistics. With re-
spect to scope and display, you can choose from the standard
statistics report to up to 10 customer-specific statistics reports.
Depending on how they are configured, statistics reports can be printed
either manually or automatically
, saved to a storage medium and sent
to the EDP system, see page 331.
Table field "Divider control"
If packages that are too heavy or too light need to be separated
, this is where you can acti-
vate a package separator or divider for each weight class.
There are no dividers available for GLM-I.
Table field "Deactivate print!"
This is where you can activate or deactivate printing or data transmission via a variety of
different channels depending on weight
.
A hook in this table field means that the respective printing channel has
been deactivated
.
Table field "Stop package on weighing conv."
If "Stop package on weighing conv
." is activated and the operating mode is "Weighing
Start/Stop", see page 274, the packages with the wrong weight stop the conveyor belt.
You can subsequently remove these packages or correct the weight of the package man-
ually. When the weight is correct, you can restart the machine.