Instruction manual GLM-I Maintenance
38.019.129.001 en 391
28
Protection and safety devices
Activity Interval Cleaning agent/lu-
bricant
Optional:
EMERG-OFF button, contactor, relay, safety
switch: Check function. Trigger EMERG-
OFF intentionally outside production
.
Weekly
Connections (cable cover tubes):
Activity Interval Cleaning agent/lu-
bricant
Check correct routing. Daily
Light barriers on conveyor belts
Activity Interval Cleaning agent/lu-
bricant
Cleaning 4 weeks Moist cloth
Pneumatic maintenance unit
Activity Interval Cleaning agent/lu-
bricant
Check compressed air input (6 bar). Monthly
Replace filter element. Depending on wear
and tear, after
2 years at the latest